Tripp Lite 1.4kW Single-Phase ATS / Switched PDU with LX review

Quick take

The Tripp Lite 1.4kW single-phase ATS switched PDU combines an automatic transfer switch with individually switched, remote-controllable outlets. It is a strong fit for data closets and server racks where you want A/B power redundancy for single-cord devices, plus the ability to power-cycle specific loads. The main caveat is that remote web interface usability has been called out as problematic by some buyers, so you should verify your access method and browser setup before committing.

Pros and cons

Pros

  • Automatic transfer switch (ATS) for redundant A/B power, with fast switchover described in milliseconds.
  • Two 5-15P inputs and 8 NEMA 5-15R outlets (15A/120V), supporting single-phase deployments.
  • Individually controllable outlets, helpful for remote rebooting network and server equipment.
  • Built-in LX platform interface for remote status monitoring and alerts, with multiple access protocols.

Cons

  • Front-outlet layout helps shallow racks, but this unit is reported as heavy and fairly deep for a PDU.
  • Remote control depends on the interface working well for your environment, so it may not be ideal if you need simple plug-and-forget management.

What buyers think

Reviewed productBuy on Amazon

Buyer feedback highlights two themes. First, users value the ATS capability for maintaining power during instability or outages, especially in setups using two UPS systems and separate backup generators. Second, buyers also comment on the physical design tradeoffs: the front outlet orientation is helpful in tighter enclosures, but the unit can be heavy and deep. On remote management, evidence is limited, but at least one review raises serious concerns about the web interface not working reliably in common browsers, which is worth taking seriously if your workflow depends on remote browser access.

What this PDU is for

This is a 1U rackmount, 120V switched PDU built around two power inputs and an ATS function. Rather than only distributing one incoming circuit, it is designed to keep loads powered from a preferred source (the primary input) and automatically switch to the secondary input when the primary becomes unstable or fails. That makes it particularly relevant for single-cord network gear (routers, switches, firewalls, network storage) and other IT loads that you want to remain online during power events.

Key setup and compatibility details

Power redundancy with ATS

The ATS maintains continuous output from the primary input under normal conditions. If the primary input becomes unstable or unavailable, the ATS switches over to the secondary input until the primary is restored and stable again. The switching behavior is described as super-fast, with switchover occurring within milliseconds, and there is also an on-board evaluation process intended to prevent unnecessary switching when quality is lower than the primary.

Switched, individually controllable outlets

All 8 outlets are individually switched, giving you the ability to manage specific loads independently. That can be useful in environments where some devices may need to be power-cycled without interrupting every connected component.

Rack fit and physical considerations

The unit is a 1U horizontal rack-mount model with front-facing NEMA 5-15R outlets. Reviews indicate that front outlets can be a practical advantage for shallow enclosures. The tradeoff is that buyers have described the PDU as heavy and relatively deep, so plan for rack stability and clearance before ordering.

Remote monitoring and control with LX

Reviewed productBuy on Amazon

The built-in LX platform interface is positioned for remote access to PDU status, including email notifications and remote monitoring. It supports multiple access paths and network protocols (including web access and common management protocols such as SNMP and secure shell options). An optional environmental monitoring add-on is referenced, but it is not included.

A realistic caution: web interface reliability

Remote outlet control is a core reason many people buy this type of PDU. While feature support is broad, buyer reports include at least one serious complaint about web interface quality and page behavior in certain browsers. If your plan is to manage the PDU primarily through a browser during critical hours, test that approach in your specific setup, or confirm you have an alternate management method that works for your team.

Pros and cons (who it suits best)

Best for

  • Small-to-mid rack environments that need A/B redundancy for 120V power using an ATS approach.
  • Network and server equipment where you want individually switched outlet control, not just power distribution.
  • Shallow rack or enclosure layouts where front outlet access is important.

Who should think twice

  • Buyers who require a trouble-free, browser-only management experience, especially if they depend on a specific web UI workflow.
  • Anyone with limited rack depth, limited ability to support a heavier 1U unit, or tight clearance constraints.

Specifications snapshot (the details that matter)

  • Output power: 1.4kW at 120V, 15A (single-phase).
  • Inputs: 2 x NEMA 5-15P (120V), supporting dual-cord redundancy.
  • Outlets: 8 x NEMA 5-15R, individually switched.
  • Form factor: 1U rack-mount, metal enclosure, front outlets.
  • Management: built-in LX platform interface, remote monitoring and email notifications, supports multiple network protocols.
  • Warranty: 2-year limited warranty (TAA compliant for GSA schedule purchases).

Verdict

Reviewed productBuy on Amazon

The Tripp Lite 1.4kW single-phase ATS switched PDU with LX is a practical option when you specifically want redundant A/B power for single-cord equipment and you also need individually switched outlet control. The feature set and outlet design are aligned with IT and network use cases, but you should pay close attention to remote interface reliability because buyer experiences around the web UI can be a deciding factor.

View latest price on Amazon: Buy on Amazon

FAQs

How many outlets does the Tripp Lite ATS switched PDU include?

It provides 8 individually switched 120V outlets (NEMA 5-15R).

Does this PDU support redundant power with two inputs?

Yes. It uses two 120V input cords (2 x NEMA 5-15P) and an ATS function to switch between primary and secondary sources when the primary input becomes unstable or fails.

Is remote outlet control included?

Yes. The outlets are individually controllable, and the built-in LX platform interface supports remote monitoring and notifications.

Is the LX interface browser-based?

It is described as a Java-free HTML5-based LX platform interface, intended for secure remote access via a web browser, along with other access protocols.

What kind of rack space does it require?

It is a 1U rack-mount unit with front outlets. Buyers note it can be heavy and deeper than many simpler PDUs, so check your rack depth and support requirements.

Who is this PDU best suited for?

It is best suited for environments that need 120V ATS redundancy for single-cord network and IT equipment, plus individually switched outlets and remote monitoring.

Specifications

Product TitleTripp Lite 1.4kW Single-Phase ATS / Switched PDU with LX Platform Interface, 120V outlets (8 5-15R), 2 5-15P 120V 12ft Inputs, 1U Rack-Mount, TAA, 2 Year Warranty (PDUMH15ATNET ) Black
CategoryElectronics > Power Accessories > PDUs
BrandTRIPP LITE
ManufacturerTRIPP LITE
Model NumberPDUMH15ATNET
ColorBlack
Item Weight5000 Grams
Number of Outlets8
Voltage120 Volts
Other Special Features of the ProductNot_Performance_Used
Maximum Current15 Amps
Power Plug TypeType B - 3 pin (North American)
Plug TypeType B
Number of Ports8
Compatible DevicesComputer, Server, Networking Equipment, Office Devices, Data Center Equipment
Amperage15 Amps
Item Dimensions L x W23"L x 21"W
ShapeRectangle
UPC112840348508 037332136428 777786391966 373321364282
Global Trade Identification Number00037332136428, 00373321364282
Mfr Part NumberPDUMH15ATNET
Built-In MediaPDUMH15NET2LX 1.4kW Single-Phase Switched PDU; Built-in LX Platform interface; Configuration cable; (8) Cable ties; Cord retention bracket; Mounting hardware; Owner’s manual
External Testing CertificationUL 60950-1, CSA, Class A, NOM
Warranty Description2 Year Limited Warranty
Unit Count1.0 Count
Enclosure MaterialMetal
Total Power Outlets8

Available variants

Style

  • 120 Volts (Standard)
  • 240 Volts

Size

  • 30 Amps
  • 20 Amps
  • 32 Amps
  • 15 Amps

Recommended next