Tripp Lite Metered PDU, 20A Dual Circuit, 32 Outlets (5-15/20R), 120V, L5-20P/5-20P, 10 ft. Cord, 0U Vertical Rack-Mount Power (PDUMV40)
Quick take
The Tripp Lite PDUMV40 is a 0U vertical, rack-mount metered PDU designed for 120V server and office equipment with NEMA 5-15/20R plugs. It splits 32 outlets across two independent 20A circuits and adds an amp display per circuit, which can make redundancy and load planning easier. The main caveat is that it is a specialized, higher-cost option best suited to buyers who actually need dual-circuit metering and organized cable management.
Pros and cons
Pros
- Two independent 20A circuits with separate current monitoring, helpful for redundant power setups.
- 32 outlets (NEMA 5-15/20R) arranged for common rack equipment.
- Color-coded, switchless design aimed at reducing accidental shutdowns and simplifying circuit identification.
- Per-circuit amp readouts make it easier to estimate current draw and cooling needs.
Cons
- Only useful if your gear and plan map cleanly to two circuits, otherwise the extra structure can be wasted.
- Metering can fail on individual units (review evidence includes an amp readout not working), so it is wise to verify functionality after setup.
- Not the smallest or simplest choice if you just need a basic, non-metered power strip.
What buyers think
Buyer feedback highlights the dual-circuit approach and the convenience of having amp metering directly on the PDU. Many reviews focus on how the per-circuit displays help when powering servers with redundant power supplies, since it is easier to check and estimate load distribution without relying on another interface. Reviewers also commonly mention the usability benefits of color-coded organization for separating backup power pathways. Overall, buyer-review evidence is generally positive, with one report indicating an amp readout issue on a unit, suggesting occasional monitoring hardware problems can occur.
Who this PDU is best for
- Server and networking racks where equipment may have redundant power supplies and you want clearer separation between feeds.
- Buyers who care about power budgeting and want to monitor current draw per circuit directly at the rack.
- People managing multi-cable layouts who benefit from color-coded inputs, cords, and outlets to keep which-circuit routing straight.
Key features that matter in daily use
Dual independent circuits with per-circuit monitoring
This metered PDU is built around two separate 20A circuits. Instead of one overall reading, you get dedicated current monitoring for each circuit, which can make troubleshooting and load balancing more straightforward when devices are assigned to different power paths.
32 rack-friendly outlets (NEMA 5-15/20R)
With 32 outlets designed for NEMA 5-15/20R plugs at 120V, it targets common North American server, networking, monitor, and general office equipment connections. The outlets are grouped so you can plan which devices land on which circuit.
0U vertical rack-mount form factor
The unit is designed as a vertical rack-mount PDU (0U), which is useful when you need to keep horizontal rack space available. A vertical layout also tends to be convenient for organizing cords down and across a rack.
Switchless design and color-coded circuit identification
A switchless design helps prevent accidental shutdowns of connected equipment. Color coding across inputs, cords, breakers, and outlets is aimed at making it easier to confirm what is on each 20A circuit, which matters when you are mapping redundant power.
Pros and cons in plain language
Pros you can plan around
- More visibility than a basic PDU because current monitoring is presented per circuit on the unit.
- Cleaner redundancy planning because the PDU is structured for two independent power paths.
- Less guesswork for wiring thanks to circuit color coding intended to reduce routing mistakes.
Tradeoffs to consider before buying
- It is not a universal fit: if your devices do not use (or you do not want to use) the dual-circuit approach, you may not benefit from the extra structure.
- Monitoring reliability is a factor: while most feedback is positive, there is at least one report of a non-working amp display on a unit, so checking the meter during setup is smart.
- Higher complexity than non-metered models: the added features and outlet organization suit rack builds, but they can be overkill for simple power needs.
Price and availability
The PDUMV40 is positioned as a higher-end metered dual-circuit PDU for rack environments. Current pricing and availability vary by retailer, so it is worth checking live listings to confirm the total cost of ownership for your setup.
Verdict
Choose the Tripp Lite PDUMV40 if you are building a rack where dual independent power circuits and per-circuit current monitoring actually help you manage redundant server power. If you just need straightforward rack power without caring about load distribution at the outlet level, a simpler or non-metered PDU may be a better fit. For the right rack design, the combination of metering, switchless operation, and circuit color coding can reduce day-to-day power management friction.
FAQ
How many circuits does the PDUMV40 have?
It has two independent 20A circuits, with separate current monitoring displays for each circuit.
How many outlets are on this metered PDU?
It provides 32 outlets designed for NEMA 5-15/20R plugs.
Is it switchless?
Yes, it uses a switchless design intended to help prevent accidental shutdown of connected equipment.
Is it meant for server racks?
Yes. The vertical 0U rack-mount design and the dual-circuit metering are especially relevant for server and networking rack setups, including systems with redundant power supplies.
What should I verify before installing it?
Verify your equipment plug types are compatible (NEMA 5-15/20R) and that your rack power plan can take advantage of the two independent circuits and the per-circuit amp monitoring.
Specifications
| Product Title | Tripp Lite Metered PDU, 20A Dual Circuit, 32 Outlets (5-15/20R), 120V, L5-20P/5-20P, 10 ft. Cord, 0U Vertical Rack-Mount Power (PDUMV40) |
|---|---|
| Category | Electronics > Power Accessories > PDUs |
| Brand | TRIPP LITE |
| Manufacturer | TRIPP LITE |
| Model Number | PDUMV40 |
| Color | Black |
| Item Weight | 3720 Grams |
| Number of Outlets | 32 |
| Voltage | 120 Volts |
| Other Special Features of the Product | Dual Independent Circuits, Color-Coded Design, Switchless Design |
| Maximum Current | 20 Amps |
| Power Plug Type | Type B - 3 pin (North American) |
| Plug Type | Type B |
| Number of Ports | 32 |
| Compatible Devices | Electrical devices with NEMA 5-15/20R plugs, such as computers, monitors, servers, and other office equipment |
| Amperage | 40 Amps |
| Item Dimensions L x W | 72"L x 6"W |
| Shape | Rectangle |
| UPC | 803982822154 021111393102 037332132505 151903595930 |
| Global Trade Identification Number | 00037332132505 |
| Mfr Part Number | PDUMV40 |
| Built-In Media | PDUMV40 Dual Vertical Circuit/Metered PDU; Mounting Hardware; Two NEMA L5-20P to 5-20P plug adapters; Owner's Manual with warranty information |
| External Testing Certification | UL60950-1 (USA) and CAN/CSA C22.2 No. 60950-1-03 (Canada) |
| Unit Count | 32.0 Count |
| Enclosure Material | Aluminum |
| Total Power Outlets | 32 |
| Special Feature | Dual Independent Circuits, Color-Coded Design, Switchless Design |
Available variants
Style
- 32 Outlets
Size
- 20 Amps
Configuration
- Dual Input
Recommended next
CyberPower PDU41001 Switched PDU, 100-120V/15A (Derated to 12A), 8 Outlets, 1U Rackmount
The CyberPower PDU41001 is a 1U, rackmount switched PDU that adds network control (local and remote) for 8 NEMA 5-15R outlets plus an LCD for at-a-glance electrical readings. It’s designed for people who want to power-cycle devices from anywhere and monitor PDU vitals, with the main tradeoff being an input current limit that’s derated to 12A in practice.
CyberPower CPS1215RMS Surge Protector, 120V/15A, 12 Outlets, 15 ft Power Cord, 1U Rackmount
The CyberPower CPS1215RMS is a 1U rackmount surge protector with 12 NEMA 5-15R outlets (front and rear) and a 15 ft power cord, built for network racks, data closets, and home office setups that need flexible plug access. It’s commonly chosen for its solid metal housing, low-profile rack fit, and practical outlet layout, with the main tradeoff being that it’s not a smart PDU and surge performance cannot be “proven” after installation.
netBooter NP-02B Remote Switched PDU with 2 Power Outlets, 120V/13A. Control via Web, telnet, or USB
The Synaccess netBooter NP-02B is a compact, independently controlled 2-outlet remote switched PDU for network equipment, designed for web and telnet (plus a USB serial port option). It supports autoping-based reboot, plus daily or weekly scheduling, but features and interfaces are not equally “friendly” for everyone, and the limited outlet count makes it a niche fit.
TRENDnet 6-Outlet Managed PDU, TPI-06, Rackmount Power Distribution Unit, UL review
The TRENDnet TPI-06 is a network-manageable, rackmount PDU with six controllable NEMA 5-15R outlets plus one bypass outlet, built for remote power control and per-outlet monitoring. It’s a strong fit for small server closets, labs, and home networking setups that benefit from scheduled power and email alerts, with the main caveat that managed features require using TRENDnet Hive.