Tripp Lite Metered PDU, 10 Outlets (8 C13, 2 C19) (PDUMH20HV)
Quick take
The Tripp Lite PDUMH20HV is a simple, rugged 1U metered power distribution unit for rack environments, offering 10 outlets (8×C13 and 2×C19) split into two load banks. A built-in digital LED meter helps you monitor current draw locally to reduce the risk of overload when you add devices. The biggest buying caveat is that it does not include switched control or built-in circuit breaker/filtering protection, so it fits best when upstream protection and cabling are already handled.
Pros and cons
Pros
- Local load monitoring: built-in digital LED meter shows current level in Amps for at-a-glance status.
- Rack-friendly design: 1U horizontal rackmount with all-metal housing and included mounting accessories.
- Practical outlet mix: 8 C13 plus 2 C19 outlets for common server and higher-draw equipment.
- Two load banks: outlets are divided into two banks to help you think in terms of load distribution.
Cons
- No outlet switching: switchless design helps prevent accidental shutoff, but you cannot power-cycle individual outlets from the PDU.
- No built-in breaker protection: it is described as not providing circuit breaker protection, so rely on upstream protection.
- Inlet and voltage matching matters: it uses a C20 inlet with an included L6-20P adapter approach, so confirm compatibility with your rack power.
What buyers think
Buyer-review evidence is limited, but the recurring themes align around usefulness and simplicity. Several shoppers describe the unit as straightforward and effective for rack deployment, especially when they need a metered PDU with a readable amp meter. Others highlight that the amp meter is easy to check at a glance and that the build feels solid for ongoing use in a server rack. There is also limited but relevant discussion about the meter behavior across common input voltages, suggesting the metering circuit does what buyers expect as long as the unit is used correctly with the intended power source.
Key features that affect day-to-day use
Real-time local load monitoring
This PDU focuses on one job: helping you monitor how much current your rack setup is drawing. The built-in digital LED meter provides local visibility into load level in Amps, which can be especially helpful when you are adding or rebalancing servers, storage, networking gear, or other IT equipment.
Outlet layout: 8 C13 and 2 C19 (two load banks)
You get 10 total outlets, arranged as 8×C13 and 2×C19, with the outlets divided into two load banks. That outlet mix covers most common “standard” power cords (C13) plus some higher-draw devices (C19) without forcing you into adapters that could increase cable clutter.
1U, all-metal rack mount, switchless design
The housing is all metal, and the unit is designed for secure 1U horizontal rack installation. A switchless approach is intended to prevent accidental shutoff from human error, which can be a practical tradeoff in busy datacenter or lab environments where accidental toggles happen.
Input and power handling you should verify up front
The PDUMH20HV is designed for a single-phase setup with 200–240V class operation, with power capacity listed as 3.2–3.8kW and 20A current. It uses a C20 inlet and an included C20/L6-20P adapter with a 12-foot cord, so before buying, confirm that your rack’s power feed, inlet type, and site voltage align with how you plan to connect it.
Pros and cons (expanded)
Why this PDU is a strong fit
- You want metering without complexity. The unit prioritizes local amp monitoring rather than smart features.
- Your rack needs an 8 C13 and 2 C19 mix. This layout is common in server and IT stacks that include a mix of standard and higher-draw power supplies.
- You value rugged hardware for daily use. All-metal construction and a rackmount form factor are aimed at long-term deployments.
- You care about load distribution. Two load banks give you a clearer way to spread equipment across outlets.
When you should look elsewhere
- You need per-outlet control or remote rebooting. This is not an outlet-switched PDU.
- You expected built-in circuit breaker protection at the PDU. It is designed as a simpler metered distribution unit, so ensure your upstream protection strategy covers overloads.
- Your power feed does not match the inlet/adapter approach. If your rack uses different inlet types or voltages, you may need a different model or a different wiring plan.
Price and availability
Pricing varies by retailer and can change frequently. If you want to check the current cost and confirm the exact model you need, use the button below to view the latest listing details.
Compatibility checklist before you buy
- Rack power feed type: confirm the available receptacle and whether you will use the included L6-20P adapter method.
- Voltage range: verify the site voltage matches the PDU’s designed operating class for 200–240V single-phase use.
- Outlet needs: count how many devices require C13 vs C19 plugs and plan your load across both banks.
- Protection strategy: ensure your upstream circuit protection and wiring meet your installation requirements.
Verdict
The Tripp Lite PDUMH20HV is a practical, rugged metered rack PDU for buyers who want clear local amp monitoring and an outlet mix that covers typical server power needs. It is best for setups where upstream protection is already in place and where you do not need smart switching, per-outlet control, or built-in breaker protection at the PDU itself. If that matches your environment, it is a straightforward way to keep power organization and load visibility under control.
FAQs
Is the tripp lite PDUMH20HV switchable?
It is described as switchless, which means it is not intended for manual or outlet-level switching. The design focus is on preventing accidental shutoff while distributing power.
Does this metered PDU include circuit breaker protection?
Buyer notes and the product positioning emphasize that it is a simpler metered distribution unit and does not provide circuit breaker protection. You should rely on upstream circuit protection for overload handling.
What outlets does it have?
It provides 10 outlets total, with 8×C13 and 2×C19, divided into two load banks.
What is the purpose of the built-in LED meter?
The meter is for real-time local monitoring of PDU output current (in Amps) so you can check the load level at a glance and avoid exceeding circuit limits as you add equipment.
Will it work in different rack voltages?
The unit is designed for 200–240V single-phase operation with specified power handling, so you should confirm compatibility with your site voltage and input wiring before installing it.
Is this a good choice for a 19-inch server rack?
Yes. It is built as a 1U rack-mount metered PDU and includes mounting accessories intended for rack installation.
Specifications
| Product Title | Tripp Lite Metered PDU, 10 Outlets (8 C13, 2 C19), 200-240V, C20/L6-20P Adapter, 3.2-3.8kW, 12 ft. Cord, 1U Rack-Mount Single-Phase PDU, TAA (PDUMH20HV) |
|---|---|
| Category | Electronics > Power Accessories > PDUs |
| Brand | TRIPP LITE |
| Manufacturer | Tripp Lite |
| Model Number | PDUMH20HV |
| Color | Black |
| Item Weight | 6.8 Pounds |
| Number of Outlets | 10 |
| Voltage | 230 Volts |
| Other Special Features of the Product | Advanced power management capability |
| Maximum Current | 20 Amps |
| Power Plug Type | Type G |
| Plug Type | Type B |
| Number of Ports | 10 |
| Compatible Devices | Personal Computer |
| Smart Home Compatibility | Not Smart Home Compatible |
| Amperage | 20 Amps |
| Item Dimensions L x W | 21"L x 12"W |
| Shape | Rectangle |
| Enclosure Material | Metal |
| UPC | 037332159014 |
| Global Trade Identification Number | 00037332159014 |
| Mfr Part Number | PDUMH20HV |
| Built-In Media | 2U metered PDU; Mounting brackets; Plug retention brackets; User manual |
| External Testing Certification | UL 60950-1 (USA, Canada), Class A (Emissions), NOM (Mexico), CE (IEC 60950) |
| Warranty Description | 2 Year Limited Warranty |
| Unit Count | 1.0 Count |
Available variants
Style
- 16 Amps
- 240 Volts
- 30 Amps
- 32 Amps
- 20 Amps / Short Power Cord
- 20 Amps
Recommended next
CyberPower CPS1215RMS Surge Protector, 120V/15A, 12 Outlets, 15 ft Power Cord, 1U Rackmount
The CyberPower CPS1215RMS is a 1U rackmount surge protector with 12 NEMA 5-15R outlets (front and rear) and a 15 ft power cord, built for network racks, data closets, and home office setups that need flexible plug access. It’s commonly chosen for its solid metal housing, low-profile rack fit, and practical outlet layout, with the main tradeoff being that it’s not a smart PDU and surge performance cannot be “proven” after installation.
WFCO WF-8930/50NPB-50 50 Amp or 30 Amp AC Distribution Center
WFCO WF-8930/50NPB-50 is an RV AC distribution center that combines a 120/240V 30/50A breaker panel with a DC fuse board in one unit. It offers up to 12 AC branch circuits and up to 15 DC circuits, with a door window, status indicator lights, and an install-focused design with a snap-in 12V fuse board for cleaner wiring.
TRENDnet 6-Outlet Managed PDU, TPI-06, Rackmount Power Distribution Unit, UL review
The TRENDnet TPI-06 is a network-manageable, rackmount PDU with six controllable NEMA 5-15R outlets plus one bypass outlet, built for remote power control and per-outlet monitoring. It’s a strong fit for small server closets, labs, and home networking setups that benefit from scheduled power and email alerts, with the main caveat that managed features require using TRENDnet Hive.
F-1005 9 Port 40A Connector Power Splitter Distributor Source Strip, 1 Input and 8 Output
The Chunzehui F-1005 is a fused 9 port DC power distribution strip built for ham shack and mobile setups that need one input split into multiple protected outputs. With an aluminum enclosure, per-fuse fault indicators, and a stated 40A input fuse with multiple output fuse ratings, it can be a practical, lower-cost alternative to higher-priced rigrunner-style units, as long as you do not need advanced voltage monitoring features.