CyberPower PDU24001 Metered ATS PDU, 100-120V, 15A (Derated to 12A), 10 Outlets, 1U Rackmount
Quick take
The CyberPower PDU24001 is a 1U metered ATS power distribution unit designed for racks that need redundancy. With dual inputs (A and B) and automatic transfer switching, it helps keep single-power-supply equipment running when incoming power becomes unstable. The key caveats are the 100-120V North American power fit, the 15A rating that is derated to 12A, and the requirement that it’s compatible with sine wave AC power sources.
Pros and cons
Pros
- Automatic transfer switch with dual NEMA inputs for power redundancy (primary to secondary and back).
- Metering and a selectable color LCD that shows operational details like amperage, voltage, and power.
- 10 rear NEMA 5-15R outlets in a space-saving 1U metal chassis.
- Switch-free design helps reduce accidental power shutdown risk.
Cons
- Must match your power environment, including 100-120V use and sine wave AC source compatibility (not for simulated sine wave).
- 15A output is listed as derated to 12A, so total draw planning matters.
- Switching and metering features add complexity versus simpler non-ATS PDUs.
What buyers think
Buyer-review evidence is limited, but the available feedback is consistently positive and focused on basic operational fit in rack setups. Reviews mention the unit performing as expected in a company data center environment and working reliably in an installed rack without complaints. There is not enough review detail to form a strong pattern about more specific day-to-day factors like display clarity, network control responsiveness, or long-term reliability, so it’s best to base your decision primarily on the documented ATS and metering feature set.
What this PDU is for
The CyberPower PDU24001 is aimed at IT closets, server rooms, and data center racks where power continuity matters. It’s built to feed connected equipment using rear-mounted NEMA 5-15R outlets while monitoring key electrical metrics and supporting automatic transfer between two incoming power sources.
If you’re powering devices with single power supplies and want an ATS-style layer between your power sources and your rack, this is the class of PDU you’re looking for. It’s also a fit when you value live visibility into electrical conditions rather than a “dumb” strip with no monitoring.
Key features that affect day-to-day use
Automatic transfer switching for redundancy
This unit uses dual power cords and separate inputs labeled as sources A and B. It is designed to switch to the secondary power source when the primary power exceeds lower or upper threshold limits, or when power fails, then switch back when the incoming power becomes stable again.
Metered LCD with selectable color
The front panel includes an LCD with selectable background color. The display is intended to provide immediate status information about PDU conditions, including amperage, voltage, and power (kW). It also includes network-related data such as an IP address, which is useful if you manage multiple PDUs or need to reference where the unit sits on your network.
10 rear outlets in a 1U footprint
With 10 rear NEMA 5-15R outlets and a 1U rackmount form factor, it’s designed to distribute AC to multiple devices while keeping cable management manageable in tight racks. The unit uses two NEMA 5-15P input plugs, each on a 10-foot power cord, which helps with placement flexibility inside the rack area.
Switch-free design
A switch-free approach is meant to reduce accidental power shutdown risk, which matters in multi-user rack environments. In other words, the goal is to keep everyday handling from leading to an unintended interruption of connected devices.
Firmware upgrade capability
The PDU supports upgradeable firmware, allowing updates for the programs that run the unit. This is a practical consideration if you rely on monitoring and want the device to stay compatible with evolving operational needs.
Power and compatibility notes to double-check
- Input and outlet type: Designed for 100-120V AC (North America) and uses NEMA 5-15R outlets with NEMA 5-15P input plugs.
- Amperage planning: While it is rated for 15A, it is specifically derated to 12A. Make sure your connected load fits within the effective limit.
- Power source type: It is compatible with sine wave AC power sources, but not compatible with simulated sine wave AC power sources. If your rack relies on certain UPS or inverter outputs, verify the waveform type before buying.
- Maximum power figures: The listing includes wattage ratings (with values shown as 1800W and 1440W depending on the provided output figures). Use your total expected load and the derated current to avoid exceeding what your configuration can safely support.
Pros and cons compared to other PDU options
Choose it if you need ATS redundancy plus metering
The biggest reason to consider the PDU24001 is the combination of automatic transfer switching and metered visibility in a rack-friendly 1U design. If your equipment is sensitive to power interruptions, and you want to monitor conditions, this class of ATS PDU can be a better fit than basic power strips.
Consider a simpler PDU if redundancy is not required
If you do not actually need dual-source transfer (for example, you only have one reliable incoming feed or you already handle redundancy upstream with other infrastructure), a non-ATS metered or even non-metered PDU may be a simpler and potentially more cost-aligned option.
Verdict: is the CyberPower PDU24001 worth it?
The CyberPower PDU24001 is a strong fit for rack deployments that need automatic transfer redundancy, metered power visibility, and space-efficient outlet density. It is especially relevant for small server rooms and network closets where connected gear has single power supplies and you want resilience when one power source becomes unstable. The main decision factor is compatibility and load planning, since it’s designed for 100-120V environments and sine wave AC sources, and it is derated to 12A for the 15A configuration.
If you’re comparing PDUs, treat this as an ATS metered power-management tool rather than a basic power strip. If your setup matches the waveform and you can keep total draw within the derated current, the feature set aligns well with continuity-focused rack builds.
Price and availability
Pricing can change, and availability may be limited. Check the current listing for the latest price and stock status before ordering.
FAQ
Does the CyberPower PDU24001 support automatic transfer between two power sources?
Yes. It includes dual inputs (A and B) and is designed to switch to the secondary power source when the primary source fails or goes outside defined thresholds, then switch back when primary power stabilizes.
How many outlets does it have?
It provides 10 rear NEMA 5-15R outlets.
Is it compatible with simulated sine wave AC power sources?
No. It is compatible with sine wave AC power sources, but not compatible with simulated sine wave AC power sources.
What voltage and amperage rating should I plan for?
It’s built for 100-120V AC. The unit is listed as 15A, derated to 12A, so your connected load should be planned around the derated current.
Is this a 1U rackmount PDU?
Yes, it uses a 1U rackmount form factor with a durable metal housing.
Does it include power monitoring?
Yes. It features a selectable color LCD that displays detailed PDU conditions, including measures such as amperage, voltage, and power.
Specifications
| Product Title | CyberPower PDU24001 Metered ATS PDU, 100-120V, 15A (Derated to 12A), 10 Outlets, 1U Rackmount |
|---|---|
| Category | Electronics > Power Accessories > PDUs |
| Brand | CyberPower |
| Manufacturer | CyberPower Systems |
| Model Number | PDU24001 |
| Color | Black |
| Item Weight | 9.6 Pounds |
| Product Dimensions | 8.45"D x 17.05"W x 1.75"H |
| Voltage | 120 Volts |
| Amperage | 15 Amps |
| Form Factor | PDU |
| Input Voltage | 120 Volts (AC) |
| Maximum Power | 1800 Watts |
| Output Current | 15 Amps |
| Output Voltage | 120 Volts (AC) |
| Power Plug Type | Type B - 3 pin (North American) |
| Connector Type | NEMA |
| Number of Outlets | 10 |
| Output Wattage | 1440 Watts |
| Wattage | 1800 watts |
| Frequency Range | 50 Hz – 60 Hz |
| Lower Temperature Rating | 32 Degrees Fahrenheit |
| Upper Temperature Rating | 113 Degrees Fahrenheit |
| Specification Met | RoHS |
| Item Dimensions D x W x H | 8.45"D x 17.05"W x 1.75"H |
| Item Dimensions | 4.5 x 21.5 x 15.75 inches |
| Battery Cell Type | Other Than Listed |
Recommended next
CyberPower PDU41002 Switched PDU, 100-120V/20A (Derated to 15A), 8 Outlets, 1U Rackmount
The CyberPower PDU41002 is a 1U, network-managed switched PDU with 8 outlets and an LCD that reports power status. It supports local and remote outlet control, plus monitoring and event notifications, making it a practical choice for small server racks and home labs that need occasional remote power-cycling.
CyberPower CPS1215RMS Surge Protector, 120V/15A, 12 Outlets, 15 ft Power Cord, 1U Rackmount
The CyberPower CPS1215RMS is a 1U rackmount surge protector with 12 NEMA 5-15R outlets (front and rear) and a 15 ft power cord, built for network racks, data closets, and home office setups that need flexible plug access. It’s commonly chosen for its solid metal housing, low-profile rack fit, and practical outlet layout, with the main tradeoff being that it’s not a smart PDU and surge performance cannot be “proven” after installation.
Tripp Lite 1.4kW Single-Phase ATS / Switched PDU with LX review
This 1U, 15A/120V switched ATS PDU is built for redundant power setups, with two 5-15P inputs and 8 individually switched front outlets for network, server, and office equipment. It adds remote monitoring and control through an LX web interface, but buyer experience around the interface appears mixed, so it is important to confirm browser compatibility for your workflow.
CyberPower PDU44001 Switched ATS PDU, 100-120V, 15A (Derated to 12A), 10 Outlets, 1U Rackmount
The CyberPower PDU44001 is a 1U rackmount switched ATS PDU designed for 100-120V setups that want redundancy for single-cord equipment. It includes 10 rear NEMA 5-15R outlets with individual remote/local outlet control, metering, and notifications, but it is not compatible with simulated sine wave power sources and one real-world report points to potential input-side failure in Source A.