Metered-Surge Protection Power Distribution Unit, 240V, L6-30P Plug, 30A, 7200watts, (6) C13 & (2) C19 Outlets, Networking, Server Rack, Heavy Industry, Crypto Mining PDU
Quick take
This 240V metered surge-protected PDU is built for rack use, with an L6-30P input plug, an onboard voltage/current display, and eight total outlets split into (6) C13 and (2) C19. It looks like a practical choice for buyers who need basic metering and outlet flexibility for server gear or mining rigs on a dedicated 30A circuit, but it is only a good match if your power setup uses the correct L6-30P connection and 240V distribution.
Pros and cons
Pros
- Onboard voltage and current meter for at-a-glance monitoring
- Surge protection plus a dedicated on/off switch for simpler daily operation
- Rack-mountable design with included mounting ears and sockets
- Flexible outlet mix: (6) C13 for standard rack PSUs and (2) C19 for higher draw devices
Cons
- Only fits specific power infrastructure, since it uses an L6-30P plug and targets 240V/30A setups
- Review evidence is promising, but long-term longevity beyond the first few weeks to months is limited
What buyers think
Buyer-review evidence points to a few consistent themes: the watt/amp (voltage/current) display is a standout feature for monitoring, the build quality is viewed as solid for the category and price point, and mounting is described as straightforward. Several buyers report smooth operation when running at or near high utilization for extended periods (including 24/7 use cases), and the outlet arrangement (especially the availability of C13 ports) matches common rack power needs. Overall, the evidence supports that the unit performs as intended in typical 240V rack and mining environments, though broader long-term reliability data is still somewhat limited.
Key features and how they affect everyday use
Metering for power visibility
The included display reports electrical values such as voltage and current, which helps you keep an eye on load without adding extra meters. That is especially helpful for dense racks or multi-rig setups where it is easy to lose track of total draw across devices.
Surge protection plus basic switching
You get surge protection combined with an on/off switch on the PDU itself. For many buyers, that means one controlled interface for powering the rack or rig down, rather than reaching for individual devices.
Outlet layout: a practical C13/C19 mix
This PDU provides eight total outlets: six C13 and two C19. In practice, that lets you plug in a combination of standard server power cords (C13) and higher-demand devices that use C19 inputs. It is a good fit when your gear power heads use different inlet types across the rack.
Rack-mountable form factor
With mounting ears and a rack-oriented design, it is intended to sit cleanly in a server rack or similar setup. The included setup pieces reduce the friction of integrating it into existing rack layouts.
Specifications that matter for compatibility
- Input plug: NEMA L6-30P (Type L), 240V
- Max input current: 30A
- Power capacity: up to 7200W
- Outlets: (6) C13 and (2) C19
- Power cord: 6 ft, 10 AWG
- Key physical info: black, rectangular form; dimensions listed as 22.95"L x 1.78"W
Important fit check: If your rack uses a different outlet type or your branch circuit is not configured for 240V with an L6-30P feed, this PDU will not be the right solution. The value of metering and the outlet layout only pay off when the power interface matches your environment.
Pros and cons, translated into buyer decisions
Best for
- People setting up a 240V rack or mining environment with a dedicated 30A circuit
- Buyers who want basic metering (voltage/current display) rather than remote monitoring
- Anyone whose devices need a mix of C13 and C19 power connections
- Users who prefer a rack-mount form factor with an easy power switch
Who should avoid it
- Buyers on a 120V-only power plan or those without an L6-30P compatible feed
- Shoppers who specifically need networked, per-outlet control or advanced remote management (this unit is built around metering and protection, not granular switching)
How it compares to other PDU options
Without naming specific competing models, here is the most useful way to compare this PDU to alternatives you might be considering:
- If you want metering: This one has an onboard voltage/current display, which can be enough for basic monitoring. Units without metering can be cheaper, but you give up load visibility.
- If you want outlet flexibility: The (6) C13 and (2) C19 mix is strong for mixed device requirements. Other PDUs may offer only one outlet type, forcing you into adapters or leaving some ports unused.
- If you want remote or per-outlet control: More advanced, networked PDUs usually cost more. If your priority is turning everything on or off and tracking load locally, this style can be a better match.
Bottom line
If you have the right 240V L6-30P input setup and you want a metered, rack-mountable PDU with surge protection and a C13/C19 outlet blend, this is a compelling option. The buyer feedback emphasizes practical monitoring, solid build quality, and trouble-free operation for 24/7 style use, with the main caveat being the need to confirm power compatibility and ongoing long-term reliability as the unit matures in your specific workload.
FAQ
Note: These answers focus on the most common purchasing questions for this specific PDU style and configuration.
Is this PDU compatible with 120V outlets?
No. This model is designed for a 240V setup and uses an L6-30P plug intended for 30A circuits. Make sure your power source and voltage match before buying.
What devices can I plug into the C13 and C19 outlets?
C13 ports are commonly used for many standard server power supplies, while C19 ports support higher-draw devices that require C19 inlet power cords. Check your equipment’s inlet type to choose the correct outlets.
Does it have a display for load monitoring?
Yes. The unit includes an onboard voltage/current meter display, which can help you monitor power conditions without adding a separate measuring device.
Is it rack-mountable?
Yes. It is designed to be rack mounted and includes mounting ears and sockets to help integrate it into a server rack.
How many outlets does it include?
There are eight outlets total, split into six C13 and two C19.
Does it include surge protection?
Yes. Surge protection is part of the unit’s feature set, intended to help protect connected equipment.
Specifications
| Product Title | Metered-Surge Protection Power Distribution Unit, 240V, L6-30P Plug, 30A, 7200watts, (6) C13 & (2) C19 Outlets, Networking, Server Rack, Heavy Industry, Crypto Mining PDU |
|---|---|
| Category | Electronics > Power Accessories > PDUs |
| Brand | Generic |
| Manufacturer | OEM |
| Color | Black |
| Number of Outlets | 8 |
| Voltage | 240 Volts |
| Other Special Features of the Product | Mountable, On And Off Switch, Surge Protection |
| Maximum Current | 30 Amps |
| Power Plug Type | Type B - 3 pin (North American) |
| Surge Protection Rating | 30 Amps |
| Plug Type | Type L |
| Number of Ports | 6 |
| Compatible Devices | Personal Computer |
| Amperage | 10 Amps |
| Shape | Rectangle |
| Item Type Name | Power Distribution Unit |
| Warranty Description | No Warranty |
| Unit Count | 1.0 Count |
| Item Dimensions L x W | 22.95"L x 1.78"W |
| Total Power Outlets | 8 |
| Special Feature | Mountable, On And Off Switch, Surge Protection |
Recommended next
Eaton BRN220GF 2 Pole 20 Amp 120/240 V BR GFCI Circuit Breaker Replaces GFTCB220
The Eaton BRN220GF is a 2-pole 20A GFCI circuit breaker for 120/240V panels, designed for plug-in mounting and ground-fault personnel protection. It can be a strong OEM-style fit for replacement projects, but it may require extra attention to wiring space and neutral routing in some panels.
RVMARINEPAT 12V Bus Bar 250A Power Distribution Block (6 x M8 Studs)
The RVMARINEPAT 12V bus bar set is a compact positive and negative power distribution solution built for high-current DC wiring (up to 250A) in 12V automotive, marine, and solar builds. It uses copper plates with stainless steel terminal studs and includes installation hardware, but it requires compatible M8 studs and correct system polarity planning.
1U 12V 20A 18-Channel Rack Mount Power Supply – 12V
A 1U rack-mount DC power distribution unit designed for CCTV, security cameras, and similar 12V setups. It provides 18 fused 12V outputs with front-panel status lighting and safety features like PTC reset protection plus surge and lightning protection, with a key wiring convenience benefit: rear-facing connections.
TRENDnet 6-Outlet Managed PDU, TPI-06, Rackmount Power Distribution Unit, UL review
The TRENDnet TPI-06 is a network-manageable, rackmount PDU with six controllable NEMA 5-15R outlets plus one bypass outlet, built for remote power control and per-outlet monitoring. It’s a strong fit for small server closets, labs, and home networking setups that benefit from scheduled power and email alerts, with the main caveat that managed features require using TRENDnet Hive.