CyberPower PDU15M2F12R Metered PDU, 100-125V/15A (Derated to 12A), 14 Outlets, 1U Rackmount, 15 Foot Power Cord
Quick take
The CyberPower PDU15M2F12R is a 1U rackmount, metered power distribution unit built for data racks, network closets, and other setups where you need multiple outlets plus real-time visibility into total current draw. It offers 14 NEMA 5-15R outlets (2 front, 12 rear), a front digital amperage display, and a rugged metal housing with cord retention for tidier routing. The main thing to double-check is the usable load, since the unit is rated 15A but derated to 12A.
Pros and cons
Pros
- Metered monitoring: front LCD shows amperage for load awareness and basic balancing.
- Good outlet layout: 14 outlets total, with 2 on the front and 12 on the rear for flexible cord routing.
- Rack-friendly build: durable metal housing and a cord retention tray to keep cables organized.
- Long reach: includes a 15-foot power cord for bottom-to-middle rack power runs.
Cons
- Power limit matters: derated to 12A output, so total connected draw needs closer planning.
- Front/back outlet spacing may affect “blocked” plugs: cable management hardware can make plugging in grounded (3-prong) devices a bit tighter when PDUs are installed very close together vertically.
- Basic metering only: it displays total amperage, not per-outlet power stats.
What buyers think
Buyer-review evidence is consistent on a few practical points. The unit is described as sturdy and heavy, with reliable day-to-day power distribution. Many users specifically like the metered front display because it makes it easier to watch overall current draw while they manage a rack. The outlet count and the front-plus-rear layout are also recurring themes, especially for setups where power must be routed from the UPS or rear area to the equipment. Cable management features, including the included retention/cable bar approach, are viewed as helpful for keeping cords organized. The most notable limitation that appears in the review evidence is occasional inconvenience plugging devices in when two PDUs are installed close together, due to tight space around the cable management bar.
Key features that affect real-world use
14 outlets with front and rear convenience
This PDU gives you 14 NEMA 5-15R outlets total, split across 2 front outlets and 12 rear outlets. That split can help you mix quick-access connections (for items you may swap or service) with bulk connections routed toward the back of the rack. It is particularly useful when your UPS or incoming power is at the bottom and you want to distribute power to equipment in the middle of the rack.
Total load visibility from the front LCD
The digital meter displays amperage on the front for real-time load monitoring. In practice, that means you can keep an eye on how hard the PDU is being worked and make adjustments to load balance as you add or rearrange devices. Note that the display is for combined current draw across the unit, not per outlet.
Rack mounting flexibility
The mounting brackets support multiple installation orientations, including horizontal or vertical configurations, plus under-counter and wall mount options. For rack users, the 1U form factor is designed to fit standard enclosures, and buyers report that the unit uses one rack space while still providing a lot of outlet capacity.
Rugged housing and cord retention for cleaner cable runs
A durable metal housing is intended to withstand the bumps and abrasions you can run into in industrial or IT environments. A cord retention tray helps keep power cords organized and accessible, which can reduce clutter, strain, and “loose cable” problems around dense racks.
Technical fit: power rating, voltage, and outlets
- Input: NEMA 5-15P plug with a 15-foot AC power cord.
- Voltage: operates in the 100-125V range (with 120V AC listed) and uses North American NEMA 5-15 connections.
- Current/power: rated for 15A but derated to 12A for output, which affects how many devices you can safely run at once.
- Outlet type: 14 NEMA 5-15R receptacles.
Buying tip: Before you choose this PDU, add up the running amps of your equipment (or approximate wattage and convert), and make sure you stay within the derated 12A practical limit for connected load.
Pros and cons (expanded)
Who this is best for
- People building or maintaining a network/server rack who want a metered PDU for at-a-glance current monitoring.
- Buyers who need more outlets in limited rack space, using a front plus rear connection layout.
- Anyone who values rugged construction and cleaner cable management with a retention tray and cord routing support.
Who should look elsewhere
- Shoppers who need per-outlet metering (this unit focuses on total amperage monitoring).
- Users who regularly plug and unplug tight, grounded plugs in very dense vertical PDU arrangements, since the cable management hardware can make access slightly cramped when multiple units are installed close together.
- Buyers expecting maximum headroom without load planning, because the unit is derated to 12A output.
Verdict
The CyberPower PDU15M2F12R is a practical, rack-first metered PDU for environments where you want multiple NEMA 5-15 outlets, organized cabling, and a front display to keep tabs on total current draw. It fits best when you plan your load with the derated 12A limit in mind and you want simple monitoring rather than advanced, per-outlet analytics.
FAQs
How many outlets does the CyberPower PDU15M2F12R have?
It has 14 outlets total, with 2 outlets on the front and 12 outlets on the rear.
What does the meter display on this PDU?
The front digital display shows total amperage draw for the load connected to the PDU.
Is this PDU rated for 15A or 12A?
It is described as 15A input, but it is derated to 12A for the output side, so your connected equipment load should be planned accordingly.
Does it support rack mounting?
Yes. It is designed as a 1U rackmount PDU and supports multiple mounting orientations using the included configurable mounting brackets.
What plug type does it use?
It uses a North American NEMA 5-15P input plug, with a 15-foot power cord.
Is this a good choice for a UPS to rack power run?
It can be a good fit for that use case since it includes a long 15-foot cord and has a layout that supports distributing power to equipment across the rack.
Does it provide per-outlet power monitoring?
No. The meter is for overall amperage monitoring rather than individual outlet-level metrics.
Specifications
| Product Title | CyberPower PDU15M2F12R Metered PDU, 100-125V/15A (Derated to 12A), 14 Outlets, 1U Rackmount, 15 Foot Power Cord |
|---|---|
| Category | Electronics > Power Accessories > PDUs |
| Brand | CyberPower |
| Manufacturer | CyberPower Systems |
| Model Number | PDU15M2F12R |
| Color | Black |
| Item Weight | 4 Pounds |
| Product Dimensions | 2.25"D x 17.5"W x 1.75"H |
| Voltage | 125 Volts |
| Amperage | 15 Amps |
| Form Factor | PDU |
| Input Voltage | 120 Volts (AC) |
| Maximum Power | 1500 Watts |
| Output Current | 15 Amps |
| Output Voltage | 125 Volts (AC) |
| Power Plug Type | Type B - 3 pin (North American & Japanese) |
| Connector Type | NEMA |
| Number of Outlets | 14 |
| Output Wattage | 1500 Watts |
| Wattage | 1500 watts |
| Frequency Range | 50 Hz – 60 Hz |
| Lower Temperature Rating | 32 Degrees Fahrenheit |
| Upper Temperature Rating | 95 Degrees Fahrenheit |
| Specification Met | No |
| Item Dimensions D x W x H | 2.25"D x 17.5"W x 1.75"H |
| Item Dimensions | 7.08 x 2.55 x 20 inches |
| Battery Cell Type | Other Than Listed |
Recommended next
APC Rack Mount PDU, Basic 100V-120V/15A, (10) Outlets, 1U Horizontal Rackmount (AP9562)
APC’s AP9562 is a basic 1U horizontal rack PDU for North American 120V setups, offering 10 NEMA 5-15 outlets on a 15A input. It’s a solid choice when you want straightforward outlet expansion for servers or an office rack, with the tradeoff that it’s not a surge suppressor, not smart, and not designed for metering or switching.
CyberPower CPS1215RMS Surge Protector, 120V/15A, 12 Outlets, 15 ft Power Cord, 1U Rackmount
The CyberPower CPS1215RMS is a 1U rackmount surge protector with 12 NEMA 5-15R outlets (front and rear) and a 15 ft power cord, built for network racks, data closets, and home office setups that need flexible plug access. It’s commonly chosen for its solid metal housing, low-profile rack fit, and practical outlet layout, with the main tradeoff being that it’s not a smart PDU and surge performance cannot be “proven” after installation.
TRENDnet 6-Outlet Managed PDU, TPI-06, Rackmount Power Distribution Unit, UL review
The TRENDnet TPI-06 is a network-manageable, rackmount PDU with six controllable NEMA 5-15R outlets plus one bypass outlet, built for remote power control and per-outlet monitoring. It’s a strong fit for small server closets, labs, and home networking setups that benefit from scheduled power and email alerts, with the main caveat that managed features require using TRENDnet Hive.
Champion Power Equipment Pro Grade OSHA Compliant Power Distribution Box, 50-Amp Twist Lock Inlet, Six 120V GFCI Duplexes, One 120/240V 30A Locking Outlet, 30A and 50A RV Adapters
This pro-grade, OSHA-compliant power distribution box is designed to turn a single 50A inlet (generator or utility) into multiple grounded, GFCI-protected 120V duplex outlets plus one 120/240V locking outlet. It is built with a heavy-duty steel frame and weather-ready enclosure, making it a practical option for job sites, outdoor events, and storm outages, as long as you have the matching inlet cord and compatible outlet/adapters.